![]() | Provides critical high temperature fire resistance All | |
| components 260 deg C rated in continuous service. | ||
![]() | Retains insulation integrity for a minimum of 15 minutes | |
| at 2000 deg F. per Mil-W-25038F | ||
![]() | Gives unexcelled resistance to abrasion, moisture, and | |
| aviation fluids. | ||
![]() | Available in multi-conductor, shielded and jacketed | |
| constructions | ||
![]() | Withstands grueling vibration and flexing | |




| Conductors |
27% nickel-coated copper per ASTM B355 concentric stranding per Mil-W-25038;(22awg and 20awg; nickel-coated high strength copper alloy per ASTM B624). |
| Insulation |
Advanced designed composite layers. |
| Color Code |
White, unless specified. |
| Temperature Ratings |
-54 deg C to 260 deg C |
| Voltage Ratings |
600 V. RMS |
| Cold Bend Quailification Test |
Passes cycling -67 deg F to 500 deg F. |
| Flame Resistance |
Integrity to 2000 deg F for 5 minutes at 125 V.RMS |
| Wet Dielectric |
Passes 1500 V.RMS after conducting in 5% NaCl solution |
| Fluid Immersion |
After conditioning in fluids ranging from aviation gasoline to hydraulic fluid, wire passes bend tests and wet dielectric tests. |
| A) Wrapped PTFE composite tape layer(s) for high temperature operation to provide a moisture-impervious and solvent-resistant barrier |
| B) Advance design composite of inorganic layers for high temperature operation and resistance to flame, radiation, and cut-through |
| C) Stranded nickel clad copper conductors for flexibility, ease of installation, and high temperature operation. 22 and 20 gauge conductors meet QPL high strength requirements. |