UL 1332
Additional Details
APPLIANCE WIRING MATERIAL
Style 1332 Single Conductor with Covering
Rating 200 deg C, 300 Vac, Horizontal flame, Oil Resistant 80 deg C (optional), Gasoline Resistant (opt)
Conductor 30 AWG – 10 AWG solid or stranded round.
Insulation Extruded FEP, 13 mils min average, 12 mils minimum at any point.
Covering (Optional) Extruded FEP, 2 mils or heavier or glass braid 7 mils or heavier.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring of appliances. In addition, the tag may also indicate the following: Suitable for immersion in gasoline; gasoline vapor; 80 deg. C in oil; and or 600 volts peak for electronic use only.
UL and the UL Logo are trademarks of UL LLC © 2014