UL 2267
Additional Details
APPLIANCE WIRING MATERIAL
Style 2267 Multiple-conductor cable using non-integral jacket
Rating 80 deg C, 300 Vac, Horizontal flame.
Conductor 26 AWG – 16 AWG solid or stranded round, tinned or bare copper.
Insulation Extruded PVC, 15 mils min average, 14 mils minimum at any point.
Assembly Four conductors.
Shield Over one or more insulated conductors. Shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid.
Jacket Extruded PVC, 15 mils min average, 12 mils minimum at any point or lacquered braid.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring.