UL 2344
Additional Details
APPLIANCE WIRING MATERIAL
Style 2344 Multiple-conductor cable using non-integral jacket
Rating 80 deg C, Voltage not specified, Cable flame.
Conductor 30 AWG min., stranded.
Insulation Labeled or complying with manufacturer’s AWM procedure.
Assembly Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering Optional. Extruded PVC, 6 mils minimum thickness, applied over the conductor assembly.
Shield Optional.
Jacket Extruded PVC, Dia 1.500 or less, 80 mils min average, 64 mils minimum at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use External interconnection of computers and electronic equipment.