UL 2386
Additional Details
APPLIANCE WIRING MATERIAL
Style 2386 Multiconductor Cable with Extruded Non-Integral Jacket
Rating 60 deg C, 30 Vac, Horozontal flame, Cable flame.
Insulated Conductor 40 AWG minimum. Labeled or complying with Manuacturer’s AWM Procedure.
Assembly Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering Optional – Extruded PVC, 6 mils minimum thickness. May be extruded over one or more groups of conductors.
Shield Optional.
Jacket Extruded PVC.
Diameter of core assembly under jacket@ Minimum average thickness Minimum thickness at any point
0.701-1.500 inch 80 mils 64 mils
@ – Major dia if cable is flat or oval.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring or external interconnection in Class 2 circuits of computers and electronic equipment.