UL 2461
Additional Details
APPLIANCE WIRING MATERIAL
Style 2461 Multi-conductor cable with extruded non-integral jacket.
Rating 80 deg C, 300 Vac, Horizontal flame, Construction A, Cable flame, construction B.
Insulation Labeled or complying with the AWM manufacturer’s Procedure.
Assembly Two or more insulated conductors, twisted pairs or groups twisted conductors twisted together. The insulated conductors or groups of insulated conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Shield Optional.
Covering Optional. A 6 mils or heavier PVC covering may be extruded over the conductor assembly.
Jacket Extruded PVC.
Diameter of core assembly under jacket Construction Minimum average thickness Minimum thickness at any point
0.700 inch or less A 30 mils 24 mils
0.700 inch or less B 45 mils 36 mils
0.701-1.000 inch A 45 mils 36 mils
0.701-1.000 inch B 60 mils 48 mils
1.001-1.500 inch A 60 mils 48 mils
1.001-1.500 inch B 80 mils 64 mils
Standard Appliance Wiring Material UL 758.
Marking General.
Use Construction A: Internal wiring of x-ray equipment or electronic equipment. Construction B: External wiring of electronic equipment in abuse areas (such as x-ray equipment and business machines).
UL and the UL Logo are trademarks of UL LLC © 2014