UL 2726
Additional Details
APPLIANCE WIRING MATERIAL
Style 2726 Multiconductor Cable with Extruded Non-Integral Jacket
Rating 40 AWG minimum. 60 deg C, 30 Vac, Horizontal flame.
Insulation Labeled or complying with Manufacturer’s AWM Procedure.
Assembly Two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Shield Optional.
Covering (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly or groups of singles.
Jacket PVC
cable dia in inches of 0.250 or less 15 mils min average 12 mils minimum at any point
0.251-0.425 dia 30 avg 24 min
0.426-0.700 dia 45 avg 36 min
0.701-1.000 dia 60 avg 48 min
1.001-1.500 dia 80 avg 64 min
1.501-2.500 dia 110 avg 88 min
2.501 dia and larger 140 avg 112 min
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring of electronic equipment.
UL and the UL Logo are trademarks of UL LLC © 2014