UL 5127
Additional Details
APPLIANCE WIRING MATERIAL
Style 5127 Single conductor with other-than-extruded insulation.
Rating 250 deg C, 600 Vac, Horizontal flame.
Conductor 24 AWG – 8 AWG, solid or stranded round.
Insulation PTFE (TFE) tape; 15 mils min average, 13 mils min at any point with two layers of served glass 10 mils min average, 8 mils min at any point.
Covering Treated Glass Braid or Treated Polyaramid Braid.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring of appliances.