UL 5193
Additional Details
APPLIANCE WIRING MATERIAL
Style 5193 Single or Multi-Fiber cable with non-integral jacket.
Rating 80 deg C, voltage not applicable, VW-1 flame.
Conductor Glass fiber, 3 mils min, 18.5 mils max, dia.
Buffer SR – SILICONE, 3 mils min average.
Assembly Single or Multiple, up to 100 bunched together. Two fiber core units may be parallel. Reinforcement Filler – (Optional) Material not specified.
Covering Optional, Thermoplastic material.
Jacket Extruded PVC, 15 mils min average, 12 mils minimum at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring or External Interconnection of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2014