Commercial (UL/CSA)

UL 5208

Additional Details

APPLIANCE WIRING MATERIAL
Style 5208 Multiple-Conductor Cable Using Extruded Non-Integral Jacket
Rating 80 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 Flame.
Buffer Labeled or complies with manufacturer’s procedure. Manufacturer shall maintain a complete description of each assembly. One or more, glass fiber core, 4 mils mininimum diameter, 6 mils maximum diameter. May be covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
Assembly One or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified.
Shield Optional.
Covering Outer – Optional PVC, 5 mils minimum thickness.
Jacket Extruded PVC
Diameter of core assembly under jacket (inches) Minimum average thickness (mils) Minimum thickness at any point (mils)
0.700 or less 30 24
0.701-1.000 60 48
1.001-1.500 80 64
1.501-2.500 110 88
2.501 and larger 140 112
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring or External Interconnection of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2014


If you don’t find what you’re looking for please contact us. The cable designs in this listing represent our standard product line. If you require special modifications or unique designs, SCC can create special cables for the most demanding applications. For custom applications please contact us.