UL 5209
Additional Details
APPLIANCE WIRING MATERIAL
Style 5209 Multiple-Conductor Cable Using Extruded Non-Integral Jacket
Rating 105 deg C, 300 Vac, Voltage not applicable to Fiber Optic, VW-1 flame.
Conductor Fiber Optic. 4 mils minimum diameter, 6 mils maximum diameter.
Buffer Labeled or complies with manufacturer’s procedure. Manufacturer shall maintain a complete description of each assembly.
Assembly One or more singles or groups of singles cabled together. The length of lay of twisted singles or groups of twisted singles is not specified. Fillers and/or barrier layer optional and their material is not specified. For composite fiber optic core – One or more glass fiber core covered with silicone resin or polyurethane coating and/or nylon or polyethylene covering. Fillers optional.
Shield Optional.
Covering Outer Covering – (Optional) extruded PVC, 5 mils minimum average thickness.
Jacket Extruded PVC
Diameter of core assembly under jacket (inches) ? Minimum average thickness (mils) Minimum thickness at any point (mils)
0.700 or less 30 24
0.701-1.000 60 48
1.001-1.500 80 64
1.501-2.500 110 88
2.501 and larger 140 112
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring or External Interconnection of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2014