Commercial (UL/CSA)

UL 5240

Additional Details

APPLIANCE WIRING MATERIAL
Style 5240 Fiber Optic
Rating 80 deg C, voltage rating not applicable, VW-1 flame.
Conductor Glass fiber, 3 mils min, 12 mils max, dia
Buffer COATING, Optional, Resin buffer.
Covering Optional. Material not specified.
Jacket Single conductor – Thermoplastic PVC 20 mils min at any point. Multiconductor – two conductors assembly jacket thickness 8 mils min at any point, and four conductors assembly jacket thickness 20 mils min at any point.
Misc. Reinforcement Filler – (Optional) Material not specified.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring or External Interconnection of Electronic Equipment.
UL and the UL Logo are trademarks of UL LLC © 2014


If you don’t find what you’re looking for please contact us. The cable designs in this listing represent our standard product line. If you require special modifications or unique designs, SCC can create special cables for the most demanding applications. For custom applications please contact us.