APPLIANCE WIRING MATERIAL
Style 20838 Multiple-conductor cable using non-integral jacket.
Rating 105 deg C, 300 Vac, Cable flame.
Insulation Labeled or complying with manufacturer’s AWM procedures.
Inner Jacket Extruded PVC, 15 mils min average, 12 mils minimum at any point.
Braid All metal, 25% minimum coverage employed between the inner and outer jackets.
Outer Jacket Extruded PVC, 25 mils minimum average, 20 mils minimum at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use External Interconnection of Appliances; Composite Jacket where the acceptability of the component is to be determined by Underwriters Laboratories Inc.