Commercial (UL/CSA)

UL 2089

Additional Details

APPLIANCE WIRING MATERIAL
Style 2089 Multiconductor Cable with Extruded Non-Integral Jacket.
Rating 60 deg C, 300 Vac, Horizontal flame.
Conductor 20 AWG – 18 AWG, solid or stranded.
Insulation Extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
Assembly Two conductors.
Shield Over one or both conductors.
Jacket Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring.