UL 2516
Additional Details
APPLIANCE WIRING MATERIAL
Style 2516 Multi-conductor cable with non-integral jacket.
Rating 105 deg C, 600 Vac, Cable flame.
Conductor 40 AWG min. solid or stranded round.
Insulation Labeled or complying with Manufacturer’s ConductorsAWM Procedure
Assembly Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Shield Optional.
Covering (Optional) A 6 mil or heavier extruded PVC covering may be extruded over the conductor assembly.
Jacket Extruded PVC
major dia in inches of 0.425 or less 45 mils min average 36 mils minimum at any point
0.426-0.700 dia 60avg 48 min
0.701-1.500 dia 8Oavg 64 min
Standard Appliance Wiring Material UL 758.
Marking General.
Use External interconnect.