Commercial (UL/CSA)

UL 2656

Additional Details

APPLIANCE WIRING MATERIAL
Style 2656 Multiconductor Cable with Extruded Non-Integral Jacket.
Rating 80 deg C, 600 Vac, Cable flame.
Conductor 36 AWG – 6 AWG. Solid or Stranded.
Insulation Labeled or complying with manufacturer’s AWM Procedure.
Assembly Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with no more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; PET; or a thermoplastic- tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
Shield Optional.
Jacket Extruded PVC
major dia in inches of 0.700 or less 45 mils min average 36 mils minimum at any point
0.701-1.000 dia 60 avg 48 min
1.001-1.500 dia 80 avg 64 min
1.501-2.500 dia 110 avg 88 min
2.501 dia and larger 140 avg 112 min
Standard Appliance Wiring Material UL 758.
Marking General.
Use External wiring.
UL and the UL Logo are trademarks of UL LLC © 2014


If you don’t find what you’re looking for please contact us. The cable designs in this listing represent our standard product line. If you require special modifications or unique designs, SCC can create special cables for the most demanding applications. For custom applications please contact us.