UL 2897
Additional Details
APPLIANCE WIRING MATERIAL
Style 2897 Multiple-conductor cable using non-integral jacket.
Rating 80 deg C, 30 Vac, Horizontal flame.
Conductor 40 AWG minimum, solid or stranded.
Insulation Labeled or complying with Manufacturer’s AWM Procedure.
Assembly Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Covering Optional. Extruded PVC, 6 mils or heavier may be extruded over the conductor assembly.
Shield Optional.
Jacket Extruded PVC.
Dia of cable under jacket inches Minimum average mils Minimum at any point mils
0.250 or less 15 12
0.251-0.425 30 24
0.426-0.700 45 36
0.701-1.000 60 48
1.001-1.500 80 64
1.501-2.500 110 88
2.501 and larger 140 112
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring.
UL and the UL Logo are trademarks of UL LLC © 2014