UL 5134
Additional Details
APPLIANCE WIRING MATERIAL
Style 5134 Single conductor with other-than-extruded insulation
Rating 250 deg C, 300 Vac, Horizontal Flame.
Conductor 22 AWG – 4 AWG. Solid or stranded for 22 AWG – 8 AWG; Stranded only for larger sizes than 8 AWG.
Insulation Nonextruded Mica tape with braid.
Conductor size Min average of Mica tape Min average of Glass Braid Treated with Silicone Varnish or TFE Finish
22 – 12 AWG 15 mils 7 mils
11 – 4 AWG 20 mils 15 mils
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal Wiring