UL 5181
Additional Details
APPLIANCE WIRING MATERIAL
Style 5180 Single Conductor with Other-than-Extruded insulation.
Rating 250 deg C, 300 Vac.
Conductor 24 AWG – 2 AWG solid or stranded round.
Insulation Skived PTFE tape
Conductor Size Minimum thickness at any point
24-18 AWG 4 mils
16-8 AWG 8 mils
6-2 AWG 12 mils
Covering Inner Covering – Two layers of glass serve over the insulation.
Conductor Size Minimum thickness at any point
24-8 AWG 10 mils
6-2 AWG 15mils
Outer Covering – Treated Glass Braid or Treated Polyaramid Braid.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring.
UL and the UL Logo are trademarks of UL LLC © 2014