UL 1477
Additional Details
APPLIANCE WIRING MATERIAL
Style 1477 Single conductor with extruded insulation and non-integral jacket.
Rating 80 deg C, 300 Vac, Cable flame.
Conductor 30 AWG minimum solid or stranded round.
Insulation Labeled or complying with Manufacturer’s AWM Procedure.
Covering Optional. A barrier layer if employed, may be a fibrous wrap, serving or braid; Paper; Nylon: oriented Polyethylene terephthalate; or a thermoplastic tape wrap.
Shield Optional.
Jacket Extruded PVC, cable dia. in inches of 0.700 or less, 30 mils min average, 24 mils minimum at any point.
Standard Appliance Wiring Material UL 758.
Marking General.
Use External interconnection.