Commercial (UL/CSA)

UL 1479

Additional Details

APPLIANCE WIRING MATERIAL
Style 1479 Single Conductor with Extruded Insulation
Rating 60 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C (optional).
Conductor 18 AWG – 2 AWG solid or stranded round.
Insulation PVC
18-8 AWG conductor size 45 mils minimum average thickness 40 mils minimum at any point
7-2 AWG 60 avg 54 min
Covering None.
Standard Appliance Wiring Material UL 758.
Marking General.
Use Internal wiring of appliances where exposed to temperature not exceeding 60 deg C; or internal wiring of appliances where exposed to temperatures not exceeding 60 deg C in air and where exposed to oil at a temperature not exceeding 60 deg C.